I. Introduction
This product is controlled electric contact pressure gauge pressure
measurement, with reliability, long-term stability of the design
that combines the world’s leading micro-processing technology and
advanced analog-digital conversion algorithm, to achieve high
precision, low power requirements. Large-screen LCD display
technology, make the data easy to read. Corrosion-resistant,
anti-vibration, can be used in a variety of complex environments.
Ceramic sensor durability, safety and health, can be used in food
hygiene industry, is to replace traditional mechanical ideal.
Widely used in a variety of liquids, gases, pressure measurement
occasions. Two threshold settings, two normally open electrical
contacts, can control and alarm devices and power devices. Factory
calibration, the user free calibration. Pressure on large-screen
liquid crystal display value, convenient on-site workers to
operate.
1. Performance indicators:
measuring substances: gas, liquid, flammable substances must be
indicated when ordering
supply voltage: DC 24V
maximum load electrical contacts: 5A (AC250V)
Reference Accuracy: 0.25 %; 0.5%; 1.0%
Operating temperature: -10 ~ 85
transport temperature: -30 ~ 50 degrees
data update rate: 3 times / sec
over Range: 10% < BR> 2. System connection diagram:
3. Assembly use:
4.1.
Meter installation instructions with dry ceramic pressure sensor,
no requirements on the installation point of view. Mouth pressure
meter into the outer rib and the use of M20 is connected to
pressure vessels, but also other types of connections can be
customized interface. Instrument Dimensions see other chapters.
4.2. When the first measurement instrument that uses a fixed
pipeline or pressure vessel in order to ensure measurement
accuracy, measurement of gas or liquid temperature preferably at
room temperature, 85instrument can also measure the following gases
or liquids, then the accuracy will losses.
4.3 Wiring
Figure 1: Wiring diagram
connection Note: Use a common point of two contacts to reach the
upper limit set value set
When the high limit contacts with the contacts common point turn,
when the contacts to reach the low limit, low limit contacts with
the contacts common point turn.
Negative side for the suspended power cable connectors, engineering
staff may be negative power supply connected with the electrical
connector, and then sealed with insulating tape.
Figure 2: Schematic diagram of panel buttons
4.4. Contact
the instrument threshold setting has two normally open electrical
contacts, the proper use of the pressure value before the action to
set the factory default values of the two movements are full scale
pressure. The lower half of the front instrument panel can be seen
three operating buttons (see Figure 2), the most right button to
enter the pressure value is responsible for setting mode, the
middle button to set the confirmation button. Press Set to enter
key (1 second after the release, you can enter the high limit
contact pressure values setup program, then the LCD screen display
is the last set value, then press the key to increase value, press
the key decrease the value, get the pressure you want to set the
value of the time, press the OK button to release more than 1.5
seconds, then store the high limit contact pressure values, and
immediately enter the lower limit value of electric contact
pressure of the setup process, an electrical contact as above
setting methods, and then press the Enter key to thoroughly after
1.5 seconds to complete the setup.
4.5.
electrical contacts to use the instrument has two normally open
electrical contacts (normally closed can be customized), when the
pressure exceeds set operating pressure value, the corresponding
electrical contacts closed and, electrical contacts can withstand
5A, 250V AC voltage.
4.6 Dimensions
4.7 Diagnosis:
This product has been range sensor failure diagnosis and protection
function, when the pressure sensors are not reliable when connected
to the circuit, instruments can automatic diagnosis to the state
and the LCD screen shows "Err" message. This status has been
maintained until the sensor to re-secure work.
When measured over a pressure range of instruments measuring range
of 10% of the time, this time for over-range condition, the
security instrument proposed to address this situation in a timely
manner. This case, the LCD screen will be displayed pressure
values, but the accuracy will be reduced.
To prevent instrument damage, often used in the use of more than
20% of the maximum pressure measurement range of the instrument.
Common fault information: